Sterilizers that are fitted with a crucible of dimensions 50 mm dia. X 50 mm depth. These glass bead sterilizers are suited for sterilizing small instruments.
Sterilization temperature is factory preset. These sterilizers are preferred by dentists, ENT professionals and dermatologists.
Specifications - Model | STERIBEAD 250 (Epoxy -Coated) |
---|---|
Size | W 125mm x D 160 mm x H 124 mm |
Crucible Size | 50mm Dia x 50mm Depth |
Unit Construction | Mild Steel, Epoxy Coated |
Pre- Set Temperature | 245-265°C |
Initial Stabilization Time | 45 minutes |
Weight (Including Glass Beads) | 2.0 Kg |
Input Power | 220-240V, 50 Hz |
Sterilizers that are fitted with a crucible of dimensions 50 mm dia. X 50 mm depth. These glass bead sterilizers are suited for sterilizing small instruments.
Sterilization temperature is factory preset. These sterilizers are preferred by dentists, ENT professionals and dermatologists.
Specifications - Model | STERIBEAD 250 (SS) |
---|---|
Size | W 125mm x D 160 mm x H 124 mm |
Crucible Size | 50mm Dia x 50mm Depth |
Unit Construction | Stainless Steel |
Pre- Set Temperature | 245-265°C |
Initial Stabilization Time | 45 minutes |
Weight (Including Glass Beads) | 2.0 Kg |
Input Power | 220-240V, 50 Hz |
Sterilizers are fitted with a crucible of dimensions 50 mm dia. X 90 mm depth. Sterilization temperature is factory preset.
These sterilizers are preferred by the following:
Specifications - Model | STERIBEAD 250P |
---|---|
Size | W 125mm xD 145 mm x H 190mm |
Crucible Size | 50 mm Dia x 90mm Depth |
Unit Construction | Stainless Steel |
Pre- Set Temperature | 250-265°C |
Initial Stabilization Time | 45 minutes |
Weight (Including Glass Beads) | 2.5 Kg |
Input Power | 220-240V, 50 Hz |
These sterilizers are fitted with digital temperature/controller and the set temperature can be manually adjusted between 250°C - 275°C. These sterilizers are specifically designed where temperature is monitored/logged daily for quality control. Sterilizers are fitted with a crucible of dimensions 50 mm dia. X 90 mm depth.
These sterilizers are preferred by the following:
Specifications | STERIBEAD 250PD |
---|---|
Size | W 125mm xD 145 mm x H 200 mm |
Crucible Size | 50 mm Dia x 90mm Depth |
Unit Construction | Stainless Steel |
Set Temperature | Adjustable Externally between 250-275°C |
Initial Stabilization Time | 45 minutes |
Weight (Including Glass Beads) | 3.0 Kg |
Input Power | 220-240V, 50 Hz |
Sterilizers are fitted with a crucible of dimensions 50 mm dia. X 137 mm depth. These Sterilizers are preferred by tissue culture production centres and used by a single operator on the laminar flow table.
Sterilization temperature is factory preset in the above units.
Specifications | STERIPOT S135 |
---|---|
Size | W 125mm x D 145mm x H 220mm |
Crucible Size | 50mm dia x 137mm Depth |
Unit Construction | Stainless Steel |
Pre- Set Temperature | 250-265°C |
Initial Stabilization Time | 45 minutes |
Weight (Including Glass Beads) | 3.0 Kg |
Input Power | 220-240V, 50 Hz |
Sterilizers are fitted with a crucible of dimensions 50 mm dia. X 137 mm depth. These sterilizers are preferred by tissue culture production centres and used by a single operator on the laminar flow table.
These sterilizers are fitted with digital temperature/controller and the set temperature can be manually adjusted between 250°C - 275°C. These sterilizers are specifically designed where temperature is monitored/logged daily for quality control.
Specifications | STERIPOT S135D |
---|---|
Size | W 125mm x D 145mm x H 230mm |
Crucible Size | 50mm dia x 137mm Depth |
Unit Construction | Stainless Steel |
Set Temperature | Adjustable Externally between 250-275°C |
Initial Stabilization Time | 45 minutes |
Weight (Including Glass Beads) | 3.5 Kg |
Input Power | 220-240V, 50 Hz |
Sterilizers are fitted with a crucible of dimensions 70 mm dia. X 150 mm depth. These Sterilizers are preferred by tissue culture production centres and used by two operators simultaneously on the laminar flow table.
Sterilization temperature is factory preset in the above units.
Specifications - Model | STERIPOT S150 |
---|---|
Size | W 150mm x D 165mm x H 250mm |
Crucible Size | 70mm dia x 6" Depth |
Unit Construction | Stainless Steel |
Pre- Set Temperature | 250-265°C |
Initial Stabilization Time | 45 minutes |
Weight (Including Glass Beads) | 5.0 Kg |
Input Power | 220-240V, 50 Hz |
Sterilizers are fitted with a crucible of dimensions 70 mm dia. X 150 mm depth. These Sterilizers are preferred by tissue culture production centres and used by two operators simultaneously on the laminar flow table.
These sterilizers are fitted with digital temperature/controller and the set temperature can be manually adjusted between 250°C - 275°C. The unit is specifically designed where temperature is monitored/logged daily for quality control.
Specifications - Model | STERIPOT S150D |
---|---|
Size | W 150mm x D 165mm x H 260mm |
Crucible Size | 70mm dia x 6" Depth |
Unit Construction | Stainless Steel |
Pre-Set Temperature | Adjustable Externally between 250-275°C |
Initial Stabilization Time | 45 minutes |
Weight (Including Glass Beads) | 5.5 Kg |
Input Power | 220-240V, 50 Hz |
Product Specification/Comparison :-
Specifications | STERIBEAD 250 (SS) | STERIBEAD 250P/250PD | STERIPOT S135/135D | STERIPOT S150/150D |
---|---|---|---|---|
Dimension | W 125mm x D 160mm x H 124mm | W 125mm x D 145mm x H 190 / 200mm | W 125mm x D 145mm x H 220mm/230mm | W 150mm x D 16 mm x H 250mm/260mm |
Crucible Size | 50mm Dia x 50mm Depth | 50mm Dia x 90mm Depth | 50mm dia x 137mm Depth | 70mm dia x 6 in. Depth |
Unit Construction | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Pre- Set Temperature | 245-265°C | 250-265°C | 250-265°C | 250-265°C |
Initial Stabilization Time | 45 minutes | 45 minutes | 45 minutes | 45 minutes |
Weight (Including Glass Beads) | 2.0 Kg | 2.5/3 Kg | 3/3.5 kg | 5/5.5 kg |
Input Power | 220-240V, 50 Hz | 220-240V, 50 Hz | 220-240V, 50 Hz | 220-240V, 50 Hz |